Testing

BE-CI is experienced in conducting multiple types of sampling and testing and has performed a variety of testing in the field for numerous projects across the United States and the Caribbean. Our field testing and sampling is utilized to assist in field verifications during surveys and evaluations or to accurately identify building failures and improper construction, wet insulation in roof systems, air and water penetration in cladding and building fenestrations to define the scope of corrective action. Our testing is performed in accordance with standard test methods and testing standards know and accepted in the industry to include:

American Society of Testing and Materials (ASTM)
American Architectural Manufacturers Association (AAMA)
Sealants, Waterproofing and Restoration Institutes (SWRI)
Exterior Insulation and Manufacturers Association (EIMA)
International Concrete Repair Institute (ICRI)
Factory Mutual (FM)

Among others

BE-CI is very experienced and capable of providing the following types of testing:

 

Infrared Thermography
Water, Door and Curtain Wall Water and Air Penetration Testing.

Thermography is a “heat diagram” of visible image using infrared wavelengths. This imaging technique is a powerful and noninvasive means of monitoring and diagnosing the condition of buildings. IR inspections can provide immediate documentation of building envelope leakage, assessment of energy inefficiency and electrical problems. Typically water on building materials will evaporate and cool. A wet spot when observed with the infrared camera is visible as a distinct cool spot or warm spot depending on the time, weather and sectional profile of the roof or wall. Roof surveys conducted at night will depict moisture under the membrane as a hot area because of solar loading that occurs during the day.

ASTM E1105 – Field Determination of Water Penetration of Installed Exterior Windows, Curtain Walls, and Doors by Uniform and Cyclic Static Air Pressure Difference


ASTM E783 – Field Measurements of Air Leakage Through Installed Exterior Windows and Doors

AAMA 501.2 – Field Check of Metal Storefronts, Curtain Walls, and Sloped Glazing System for Water Leakage

Air Sampling for Mold Investigations and Indoor Air Quality (IAQ Testing)

Chloride Contamination Analysis for Concrete Structures

Dry-Film Thickness Paint Coating Verification

Sealant Field Adhesion Testing

 